Find more info on Pump Over run at the bottom of this page. Boiler Connections. Older fully pumped central heating systems and some newer ones often pick up an electrical power supply from the existing immersion heater circuit and the boiler is wired by running a 4 core cable from a Y or S plan wiring centre. HTB1giN6GVXXXXc.XVXXq6xXFXXXl/2178326/HTB1giN6GVXXXXc.XVXXq6xXFXXXl.jpg' alt='Central Heating Pump Installation Instructions' title='Central Heating Pump Installation Instructions' />TURBOmax VUW 2421 E TURBOmax VUW 2821 E Wall hung room sealed fan assisted combination boilers INSTRUCTIONS FOR INSTALLATION AND SERVICING HEATING, CONTROLS, HOT WATER. This includes a LNE permanent supply and a switched supply to fire the boiler. A 3 pole switch s often positioned next to the boiler to electrically isolate it for servicing. Remember that this only isolates the supply and switched feed to the boiler if it is connected correctly. I would always prefer to find the main system electrical supply and switch off there before removing the panels. A 5th core or a seperate 3 core is needed where a remote pump is installed. The diagram below shows typical boiler connections used in this type of installation Potterton Boiler Control Wiring Connections. Modern boiler connection panels layouts and terminal identifications differ and can at first be confusing. You need to remember that most conventional system boilers control the pump over run and they are also the source of the electrical feed to any controls. For this reason the main heating system supply would go to the boiler first. The wiring terminal examples shown below are typical of those used by modern manufacturers such as Worcester Bosch where the main electrical power supply feeds into the boiler via LNE terminals and control wiring runs out from the boiler to a room thermostat or programmer. Note You will need to consult the wiring diagram for your particular boiler to identify how your particular system requires connecting. Bosch Worcester Boiler Connections. L N E terminals Electrical input supply for the whole system. Use 3 core heat resisting cable from a double pole switched 3 amp fused spur unit. The System Controls terminalsThese 2 terminals normally have a factory fitted link between them. When controls such as a room stat, programmer andmotorised diverter valves are installed, this link needs to be removed to allowthem to be connected. Bosch Worcester Boiler Control Connections Diagram. Here are some more typical boiler control terminal connection identifications LS L1 RT Supply Out terminal This is normally a 2. It is usually fed from within the boiler and does not require any other external or auxiliary supply. This could be used as the live supply to a roomstat, programmer or wiring centre. LR L2 RT Return terminal This connection needs a supply back from the controls to fire the boiler. Installation Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokra is a licensed member of the Benchmark scheme which aims to improve the. Small duct high velocity central air conditioning, and other related heating, ventilation and airconditioning products offered by SpacePak. This could be a 2. N NS terminal This is a 2. Neutral output connection. Use this forroom stats, programmers,wiring centres and any controls that need a neutralconnection. Pump L N terminals The boiler controls the running of the pump from these terminals. A pump within the boiler casing may already be connected here. A remote pump will need to be wired back to here. Frost Protection. Frost Thermostat terminals usually have a factory fitted link between them. When a frost stat installed this link needs to be removed to allow connection of frost controls. FP1 FS terminal This is the supply out to the frost stat. FP2 FR terminal This is the return back from the frost stat. Bosch Worcester Boiler Frost Stat Wiring Connections Diagram. Other systems may not have a dedicated wiring connection terminal for a frost stat. In this case you could simply connect the frost stat between the systems permanent live and the boiler switched supply to directly fire the boiler in freezing conditions. See diagrams below. Note Some Heating Controls and Frost Stat connections may only be suitable for a 2. Be sure to check your boiler instruction manual. Here are some more examples of boiler wiring connections used in other systems such as Ideal Heating Ideal Heating Systems Boiler Wiring Connections. I hope this info on boiler wiring was useful. Please feel free to leave your comments below. Find more Central Heating Guides. Find Central Heating Controls on EBAY Some more useful info from Mike The Boiler Man about the reason for Pump Over Run Condensing boilers have a device built into them to control the pump, keeping it running for a few minutes after the burners have shut down to distribute the residual heat and protect the fragile high performance heat exchanger, in case you were interested. This means running an extra cable from the boiler location to the pump location usually next to the hot water cylinder upstairs in the airing cupboard. Installing this extra cable can be time consuming and disruptive to carpets and decorations.